Torch on Bitumen Membrane for Concrete Roof

Product Details
Customization: Available
Basement: Polyester/Fberglass Reinforced
Warranty: 1 Year
Still deciding? Get samples of US$ 3/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (19)
  • Torch on Bitumen Membrane for Concrete Roof
  • Torch on Bitumen Membrane for Concrete Roof
  • Torch on Bitumen Membrane for Concrete Roof
  • Torch on Bitumen Membrane for Concrete Roof
  • Torch on Bitumen Membrane for Concrete Roof
  • Torch on Bitumen Membrane for Concrete Roof
Find Similar Products
  • Overview
  • Product Introduction
Overview

Basic Info.

Model NO.
CH-SBS
Material
Modified Bitumen
After-Sale Service
Online Technical Support
Thickness
2mm 3mm 4mm 5mm
Sales Mode
Professional Factory Since 1994
OEM
Available
Surface Material
PE/Aluminum Film/Sand/Granulars
Application
Construction Building Waterproofing
Transport Package
with or Without Pallet Packing
Specification
1m x 10m /roll
Trademark
Chenhua
Origin
Shandong, China
HS Code
68071000
Production Capacity
10000000PCS/Year

Product Description


Torch on Bitumen Membrane for Concrete Roof

Product Introduction

 

Torch on Bitumen Membrane for Concrete Roof

Bitumen, often celebrated as asphalt, is a dense, jet-black, and considerably viscous liquid or semi-solid born from petroleum. Renowned for its extraordinary waterproofing credentials, it finds extensive application within the construction realm. Bituminous membranes stand as the quintessential choice for waterproofing pursuits across roofs, basements, subterranean structures, bridges, and a myriad of other constructions. Primarily, two authoritative techniques exist for applying bitumen membranes.
These techniques include the Torch-on method and the Self-adhesive technique.
Torch-on bituminous membranes offer a versatile, simple-to-use solution suitable for diverse climatic conditions. Upon application, CHENHUA membranes seamlessly coalesce into an impermeable, watertight barrier, robustly bonded to the underlying surface.

Torch on Bitumen Membrane for Concrete Roof

 
Top cover Polyethylene Film or other films Sand or other granular
Popular thickness 3mm 4mm 5mm 3mm 4mm 5mm
Reinforcement PY or Fiberglass PY or Fiberglass
Size/roll 1mx10m ,1mx8m ,1mx7.5m 1mx10m, 1mx8m, 1mx7.5m

Torch on Bitumen Membrane for Concrete RoofTorch on Bitumen Membrane for Concrete Roof
Torch Down Bitumen Waterproof Membranes find widespread utilization across various construction grades for both waterproofing and seepage-proofing endeavors. Suitable for both visible and hidden areas, applications include flat roofs, sloped roofs, subterranean areas, tunnels, bridges, parking lots, reservoirs, and beyond.

Torch on Bitumen Membrane for Concrete Roof

Application method:
1. Substrate:
Ensure that the substrate is impeccably clean, dry, and free from any contaminants, thoroughly prepared for optimal results.
Every speck of dust and any loose, friable material must be meticulously removed.
Blowholes and voids should be fully exposed and meticulously repaired thereafter.

2. Primer:
Prior to laying the membrane, administer a primer. Cleanse the substrate using a dust catcher or blower, and apply a treatment primer to guarantee optimal waterproofing, ensuring cohesive dust consolidation and superior adhesion.
3. Membrane placement:
*With precision, unroll the torch-on membrane and align it accurately prior to commencing torching or bonding.
*Each membrane should be laid out in parallel fashion, staggered by at least 1 meter to avoid overlapping joints.
*Ensure end-to-end overlaps are alternated, never aligned along a single trajectory.
*Initiate installation at the lowest slope height, commencing with drains, downpipes, or other detailed structures.
*During the torching process, simultaneously heat both the membrane and substrate, focusing on the roll and overlapping zones.
*Overlaps should be welded with meticulous precision, ensuring a fine trickle of melted mix, about 1 cm wide, appears along the overlap line.

4.Use a roller to exert firm pressure on the membrane surface, ensuring strong adhesion and secure placement.

Torch on Bitumen Membrane for Concrete Roof
Attention:
1. Assure the substrate's dryness and cleanliness. Refrain from operations on rainy or snowy days.
2. Avoid operations during strong winds exceeding grade 5.
3. Construction is inadvisable at temperatures below 5°C.
4. Should rain or snow occur during construction, ensure protective measures are in place for the membrane already laid.
5. All personnel must don specialized uniforms for safety during installation. Fire control equipment remains indispensable.

Torch on Bitumen Membrane for Concrete RoofTorch on Bitumen Membrane for Concrete Roof

Packing and shipping:
1. Store membranes in environments that are dry, well-ventilated.
2. Segregate different types of membranes for storage.
3. Under mundane conditions, the storage tenure lasts one year from the production date.
4. During transport, membrane rolls should be stored upright, shielded from sunlight and precipitation.

 
With pallet Seaworthy plywood pallet packing, 20pallets/20ft container
Without pallet Plastic bag per roll, common or OEM with customer brand



Torch on Bitumen Membrane for Concrete Roof
Torch on Bitumen Membrane for Concrete Roof
Torch on Bitumen Membrane for Concrete Roof
Torch on Bitumen Membrane for Concrete Roof


 
Torch on Bitumen Membrane for Concrete Roof
Torch on Bitumen Membrane for Concrete Roof
Torch on Bitumen Membrane for Concrete Roof


Torch on Bitumen Membrane for Concrete Roof


Torch on Bitumen Membrane for Concrete Roof
Torch on Bitumen Membrane for Concrete Roof1) What's the popular size for Torch-on bitumen membrane?
-3mm x 1m x 10m with PE or sand granular top.
-Experience the premium quality of our membranes, featuring a robust 4mm thickness, a convenient 1m width, and a generous 10m length, available with either a protective PE layer or a stylish sand granular finish.


2) What's the fundamental difference between SBS and APP?
-SBS and APP are innovative modifiers tailored to elevate the performance of waterproof membranes. SBS modifiers are engineered to dramatically enhance cold resistance, making them perfect for frigid environments, while APP modifiers are crafted to boost heat resistance for high-temperature conditions. Though they may appear similar, each offers distinct functional advantages that cater to different environmental demands.

3) Is OEM available?
-Certainly! We warmly invite you to discover our comprehensive OEM services, which are available at your convenience.
Simply share your logo with us, and we can craft a custom design tailored to your brand. Alternatively, provide us with your finalized design, and we will print it with precision on PE film, ensuring it is beautifully packaged for a pristine delivery experience.


4) Are you a factory?
-Absolutely, Shandong Chenhua Waterproof Co., Ltd. is a highly experienced and professional factory dedicated to manufacturing a wide variety of waterproof materials since 1994. Nestled in the illustrious China Waterproof Town-Taitou-our establishment offers a comprehensive range of products that cater to a multitude of waterproofing applications, from concealed to exposed surfaces.

5) What is the delivery time?
-Generally, orders are efficiently fulfilled within a swift 10-day period post order confirmation. However, please be mindful that delivery timelines may fluctuate depending on specific project requirements and the volume of orders placed.

Torch on Bitumen Membrane for Concrete Roof

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier